Structured cabling, certified to the link

Twenty-four years of copper and fibre installation, now inside Purview DC. From a single office floor to a 100-rack GPU hall: survey, design, install, test and document, with every link certified before handover.

24 yrsof structured cabling delivery, EDF Purview, Sydney
185,000+copper and fibre links terminated, tested and certified
Level VIcopper certified on Fluke DSX-8000; fibre on calibrated MPO equipment
Overview

The foundation everything else runs on

Structured cabling is the physical layer of business connectivity. Done well it is invisible for twenty years; done badly it is the cause of every intermittent fault nobody can find. Purview's cabling practice began in Australia in 2002 as EDF, joined Purview Group as EDF Purview and now delivers worldwide under Purview DC: Cat6 and Cat6A copper, single-mode and multi-mode fibre, MPO trunks and InfiniBand fabrics for data centres, offices, campuses and industrial sites.

Data centres

Structured and point-to-point cabling for GPU halls, hyperscale, sovereign and enterprise sites. MPO-8/12/16/24 fibre, InfiniBand and RoCE fabrics, patch panels, dressing and labelling to the rack build instructions.

Offices and campuses

Cat6A horizontal cabling, backbone fibre, wireless survey and deployment, AV and security cabling, for new builds, fit-outs and relocations.

Industrial and education

Plants, warehouses, laboratories and universities, including the Macquarie University Law School (Michael Kirby Building) delivered on CommScope.

Why it sits in Purview DC

The same crews that cable a GPU floor cable your office. One certified-installer standard, one test method, one handover pack, whichever the site.

Eight stages →
What we deliver

Survey to support, under one team

Design and estimating

  • Site survey and assessment of the existing infrastructure
  • Cabling architecture designed for the workload and for growth
  • Design specifications and bill of materials
  • BIM where the project uses it, so decisions are made early and changes are not made on site
  • Fixed-price estimate with options

Installation

  • Certified technicians from start to finish
  • Cat6 and Cat6A copper; OS2 and OM4/OM5 fibre; MPO trunks and cassettes
  • Containment, pathways, cabinets and racks
  • Dressing, labelling and documentation to a single scheme
  • Minimal disruption in live buildings and live halls

Testing and certification

  • Every copper link certified to Level VI on Fluke DSX-8000
  • Every fibre link OTDR and insertion-loss tested; MPO polarity verified
  • Results submitted for manufacturer warranty (up to 25 years)
  • As-builts, test results and asset register in the handover pack

Project management

  • A dedicated project manager from consultation to handover
  • Scheduling around occupancy and change windows to minimise downtime
  • Materials, logistics and crew resourcing
  • Quality gates: engineering release, site validation, installation verification, independent acceptance QA
  • Risk assessments and method statements for every site

Smart hands and support

  • IMACD: install, move, add, change, decommission
  • Infrastructure refresh: cabinet, rack and stack
  • Relocation and data migration
  • Cable patching and tidy-up
  • Audit, asset management and labelling
  • IT asset recycling and secure erasure

Network and AV infrastructure

  • AV over IP, HDBaseT and conferencing room cabling (Audio Visual →)
  • Enterprise firewall refresh
  • Core and access switch deployment
  • Wireless surveys and deployment, WiFi6
  • Network configuration and validation
  • ICT infrastructure migration
AI Infrastructure →
How we work

Preparation-first, the same as a GPU floor

Cabling material is received, verified, pre-terminated where possible and labelled in prestaging before it reaches the site, which is why our installs finish on the date and our test sheets come back clean.

Survey and designSite walk, existing estate, pathways, outlet and rack counts, architecture and estimate
PrestageMaterial receipt, pre-termination, labelling, engineering release
Install and certifyContainment, pulls, termination, dressing; Level VI copper and OTDR fibre on every link
Handover and supportAs-builts, warranty registration, asset register; smart hands under contract
Case in point

Macquarie University Law School, Sydney

Structured cabling for the Michael Kirby Building: teaching, workplace and research spaces plus a suspended moot court, delivered on CommScope as a certified installer and documented in a CommScope case study. Alongside it, the same practice has certified 185,000+ links on AI data centre floors in Australia, the Middle East, the US and India.

Certifiedinstaller delivery, manufacturer case study
Certified installer

Vendor-neutral, manufacturer-certified

We hold installer certification across the leading cabling systems, so the recommendation is made on your requirement and your warranty, not on one supplier's catalogue.

SiemonCodecomAPCFluke Networks

Standards we install to

  • ISO/IEC 11801 and TIA-568 structured cabling
  • AS/NZS 3080 and ACMA cabling rules in Australia
  • BS 6701 in the UK
  • Manufacturer-specific installation and warranty programmes

Assured delivery

  • CMMi Level 5, ISO 27001, ISO 20000, ISO 9001, ISO 14001
  • UK Crown Commercial Service supplier
  • Security-vetted crews for government and finance sites
  • Public and products liability, workers' compensation, professional indemnity, cyber liability

Where

  • Australia and New Zealand from Rydalmere, Sydney (EDF Purview)
  • India from Hyderabad, Chennai and Noida
  • UK and Europe from Edinburgh and Warsaw
  • Gulf and APAC from Dubai and Singapore
Locations →
Why clients choose Purview for cabling

Cabling at the core, not an add-on

24 years, same discipline

A practice that started in 2002 and has cabled offices, universities, hospitals and now the densest AI halls in the world, without changing its test method.

Certified on every link

Not sampled. Every copper link to Level VI, every fibre link OTDR and insertion-loss tested, results in your handover pack and registered for warranty.

One partner from outlet to operations

The cabling crew, the rack and stack team, the commissioning engineers and the 24×7 smart hands all sit in Purview DC, so there is one owner when something needs fixing.

EDF Purview, Australia ↗  ·  Purview DC services ↗

Project enquiries

Build your network on the strongest foundation.

Send us the site, the number of outlets or racks and the target date. We will survey, design, estimate and install, then certify every link before handover.